Pipe with as little restriction as possible. By minimizing restrictions, the air or
vapor eliminator will work as efciently as possible.
¾" (or larger) pipe/hose is recommend to vent air or vapor to the storage tank.
½" pipe/hose is recommended for piping to an air check or differential valve (⅜"
is acceptable).
If using hose, choose a type that will not collapse in on itself (heater hose,
hydraulic hose, etc.).
Be sure a catch vessel or spit receptacle is vented with a vent no smaller than
the pipe/hose connected to it. (Catch vessels vary in size but most are between 2
and 5 gallons.)
Pipe the air eliminator vent port into the top of the catch vessel for maximum
efficiency.
Liquid Controls recommends that catch vessels be drained regularly and that the
volume is indicated with a sight gauge, for example.
